ACQ 2016-1

Direct reduced iron (DRI)

  • Cargo spaces should in an inert condition with less than 5% oxygen, and hydrogen at less than 1%.
  • DRI should be treated with an oxidation-inhibiting process.
  • Carriage of DRI should always be under a nitrogen blanket.
  • Records should be frequently taken of the levels of hydrogen and oxygen in each cargo space.
  • DRI should not be hot or damp when loaded. DRI in excess of 65 degrees centigrade should never be loaded.
  • DRI should be trimmed to reduce amount of cargo surface area and also reduce void space in the cargo which will allow hot gas to move upwards.